Are you replacing a lamp or a complete light?
The object in the existing installation
Replacing a traditional floodlight with LED can mean three different jobs: changing a lamp in a retained fitting, installing an identified retrofit kit, or replacing the complete luminaire. Choose the route around what can usefully remain. Buying a lamp first can leave the housing, optics or controls that prompted the project unchanged.
A replaceable-lamp fixture has a host assembly that continues to matter after the source changes. A complete LED floodlight is supplied as an assembly with its own light source, regulating electronics, optical system and enclosure. A kit has its own defined conversion scope. These distinctions determine which existing parts the proposal relies on and who is responsible for the resulting arrangement.
Electrical assessment and installation belong to competent personnel using the applicable instructions and local requirements. The route comparison here concerns project scope, useful lighting and purchasing decisions, rather than a procedure for altering existing wiring.
Keep the useful lighting task as the baseline
The target and the operating periods
Describe what the existing light is supposed to illuminate. A loading position, building facade and vehicle route can sit close together while needing different distributions and operating periods. Retain the task in the comparison, even when the old installation has performed poorly.
Record the areas that need light and the periods when they are used. Separate a daytime delivery problem from an overnight perimeter requirement. If the scope has changed since the original installation, use the new requirement rather than assume a source replacement should reproduce the old result.
Why a brighter catalog total may not solve the job
A higher lumen total can still send too much light beyond the target or leave an important area uneven. The existing reflector, a new lamp’s emitting shape and a complete fixture’s optics can distribute light differently. Treat the useful result at the target as the comparison, not simply a larger number on the carton.
For a project with an existing lighting calculation, the proposed luminaire’s relevant photometric data can be evaluated against that layout. Where no such record exists, the task and site geometry need defining before a like-for-like performance claim has meaning. VST’s floodlight coverage explanation develops this distribution question separately.

Compare the three replacement routes
A lamp compatible with the retained host
A lamp-only change is attractive when the retained fixture is suitable, useful and supported for the proposed source. The lamp base is only one part of that relationship. The host’s physical envelope, electrical arrangement, thermal conditions and optical behavior still affect the outcome.
If the host itself is the problem, retaining it transfers that problem into the new purchase. This route makes more sense when the assessment supports keeping the enclosure and the resulting light distribution serves the brief.
An identified kit or a new complete fixture
An LED retrofit kit is a defined product with instructions identifying the intended conversion. UL Solutions’ retrofit-kit guidance explains why the identified kit and host conditions matter. It does not make every collection of LED parts a supported conversion.
A complete replacement changes the supplied luminaire instead. That can address a housing or optical limitation, but brings mounting, connection, aiming and control integration into the project scope.
| Route | What remains | Useful condition | Reason to rule it out |
|---|---|---|---|
| Lamp change | The host fixture and its relevant systems | A supported lamp/host arrangement meets the task | The retained host is unsuitable or causes the unresolved problem |
| Identified retrofit kit | The parts specified in the kit’s host scope | The kit identifies the applicable host and conversion | The actual host or required result falls outside that scope |
| Complete luminaire | Only the surrounding infrastructure accepted for reuse | The project needs a different complete assembly | The proposed fitting cannot meet the site or integration requirement |
The parts that remain must still serve the new arrangement
Housing, holder and optical condition
A retained housing has to remain useful for its proposed service. Damage, deteriorated sealing or an unsuitable internal arrangement can change the route decision. A lamp purchase does not renew these parts. The assessment should identify the actual condition rather than infer it from the fixture’s age alone.
Likewise, the optical result depends on more than whether the new source fits inside. A changed source position or shape can affect how the retained optical system uses its light. When that relationship is unresolved, apparent savings in the supply list may buy a result that still needs replacing.
Separate the condition assessment from the source proposal. The first asks whether the relevant retained parts can continue in service. The second asks whether the identified new source or kit works within that arrangement. A clean-looking housing answers neither question on its own, while an approved source proposal cannot repair unrelated deterioration in the host.
Access and the mounting interface
Consider the support that would remain and the space needed to reach the fitting. Repeated access can become a significant project obligation when lights sit above a working delivery area. Compare the routes on the actual retained hardware and the work each requires; do not assign the same access scope automatically.

Fit includes the light, the support and the aiming space
Envelope and the movement needed for the intended angle
A dimensioned body outline may exclude the support bracket or the space occupied when the light is tilted. Compare the proposed assembly in its intended position, especially where a canopy, wall return or neighboring equipment restricts movement.
For a retained host, internal fit belongs to the applicable source or kit instructions. For a new luminaire, external dimensions and the bracket arrangement help establish whether the assembly can occupy the proposed location. Neither comparison should rely on scaling an undimensioned product photograph.
Compare dimensions from the same reference points. A luminaire width, bracket span and space between existing supports describe different distances. Draw the actual interfaces in the project detail so a body dimension is not accidentally used as a mounting dimension. This is especially helpful when an old fixture is being replaced by a substantially different housing shape.
The connected space around the fitting
A cable exit or adjacent connection enclosure also occupies space. The aiming position needs a supported connection arrangement rather than a cable pulled tight to achieve the angle. Include the surrounding detail in the design assessment, not only the face of the light.
These physical questions can change the supply scope before energy savings enter the discussion. A smaller power rating offers little help if the proposed assembly cannot be accommodated in the available position.
Compare output and distribution on the same job
Complete-luminaire data versus lamp output
A lamp lumen rating describes the source under its stated conditions. A complete-luminaire output describes a different measurement boundary. When comparing a retained-host route with a new fixture, keep those boundaries visible rather than place both totals in one unqualified column.
VST’s published FL20-100W entry, for example, identifies a complete fitting rated at 100W and 15,000lm. That catalog record is a product starting point. It does not establish the light delivered by a proposed replacement layout or the output of a lamp inside an old reflector.
Equivalent target and operating conditions
Compare the proposed distribution against the same target, mounting position and relevant operating state. If an option needs a different position or more fittings, carry that change into both the lighting and cost comparison. Otherwise the apparent advantage comes from changing the job being priced.
The operating comparison should also distinguish a steady working scene from a source’s behavior when first turned on or after an interruption. Describe the required function in the lighting brief and use the proposed product’s information to establish it. The old source’s nominal power cannot answer that question for a new assembly.
| Evidence | What it describes | Use in the decision |
|---|---|---|
| Lamp output | The specified source | Part of a supported retained-host assessment |
| Complete-luminaire output | The supplied assembly | A product-level comparison with the same boundary |
| Photometric distribution | Where the luminaire sends its output | Evaluate the actual target and proposed geometry |
| Project calculation | The stated layout, surfaces and operating conditions | Compare whether each proposal performs the same lighting task |

Controls can change the preferred replacement route
Keep the intended switching or dimming behavior
Replacing the light can also change when or how it operates. Identify whether the job needs ordinary switching, daylight operation, scheduling or reduced output. A new fitting that cannot produce an existing required scene may need a different control version or arrangement.
Distinguish a catalog’s available options from the version included in an offer. The FL20 records list DALI and DMX512 options. They do not make every supplied fitting accept either system, and they do not supply the surrounding controller automatically.
What would make a retained arrangement unsuitable
A retained control can be a useful asset when its role and the new equipment are supported together. Where the new source changes that relationship, include the control work in the route decision. A lamp-only quote with an unresolved control requirement is not yet comparable with a complete solution that includes it.
Read a complete-fixture record before treating it as a bulb
A named product and its supplied parts
Use the FL20-100W product record as a reading exercise. Its rated input, complete-light output, driver field, enclosure and bracket identify a luminaire proposal. The comparison object is the whole fitting, not a 100W lamp for an unspecified old housing.
That reading changes the next project question. Instead of asking whether its base fits an existing holder, evaluate how the complete assembly serves the target and integrates with the proposed support and controls. Model-specific documents must resolve those details before selection becomes an installation decision.

Work through a route decision for a retained outdoor installation
Declare the existing condition and the changed requirement
Consider this hypothetical survey outcome: the assessed housing is not suitable for retention, while the site still needs the same defined loading-area task. No product-specific measurements or prices are assumed. The deciding input is the non-retainable host, not a guessed wattage-equivalence factor.
Choose what must be replaced and explain why
| Option | Relationship to the failed retention condition | Selection result |
|---|---|---|
| Change the lamp | Depends on keeping the assessed unsuitable host | Does not resolve the stated condition |
| Fit a kit in that host | Still depends on a host the survey rules out | Not a solution for this declared scope |
| Replace the complete fixture | Can replace the unsuitable host assembly | Prioritize this route, then evaluate the proposed model and layout |
The result selects a project direction, not a particular certified combination. The new fixture must still meet the target, environmental, mounting and control requirements. If the survey instead supported retaining the host, a supported lamp or kit could remain in contention; the conclusion changes with that input.
Compare the whole replacement scope before ordering
Products and access work included in the comparison
Obtain comparable scopes before comparing totals. A source-only offer and an installed complete-fixture offer contain different work. The FEMP exterior-lighting purchasing guidance provides useful context for energy and life-cycle comparison, but the actual project costs and operating assumptions remain local inputs.
The retained items and later service responsibility
| Cost or responsibility | Scope to compare | Why it matters |
|---|---|---|
| Supply | Lamp, identified kit or complete fitting, with the offered control version | Establishes what is actually purchased |
| Access and work | The visits and installation work included in the offer | Prevents omitted site work from appearing as a product saving |
| Retained infrastructure | The parts assessed for reuse and work still required | Locates obligations outside the new product |
| Later support | Product scope, service route and applicable written terms | Clarifies which assembly is supported after the change |
A useful replacement proposal therefore names the route, the supplied object and the lighting task it will serve. With those fixed, energy and service comparisons become decisions about equivalent solutions rather than competing carton prices.