Which floodlight wiring drawing applies to the job?
The luminaire and the selected control version
Start with the complete floodlight model and the behavior you need from it. A fitting that follows a wall switch, one that responds to daylight and one that dims under a lighting controller may need different equipment and different drawings. The useful document identifies the supplied version rather than simply showing a rectangular light with several wires.
Also establish the product being supplied. A complete mains-powered floodlight, a replaceable lamp, a solar assembly and a light source with a separate driver are different objects. A drawing for one cannot describe all four. This distinction helps a project buyer order the correct assembly before an installer encounters a different arrangement on site.
A useful document comparison starts with the model coverage, control designation and revision. Match the drawing’s covered products to the offered assembly. If it identifies several versions, follow the distinction it makes between them. A family name on a brochure is less specific than a drawing that names the supplied driver and control arrangement.
Electrical design and installation require competent personnel, applicable product instructions and local requirements. The discussion below helps you interpret system roles and prepare a functional plan; it does not provide terminal connections, conductor selection or a site installation drawing.
Find the power input, driver and light source
The complete fitting and its internal regulation
In a complete LED floodlight, the incoming supply reaches electronics that regulate the LED source. The source, optical parts, enclosure and mounting form the supplied luminaire. Some of those relationships are inside the closed body, so an outside photograph cannot identify every internal connection.
Keep the drawing’s boundary in view. If a diagram encloses the driver and LEDs within one fixture symbol, its external connections concern that complete product. A separately drawn driver creates another equipment boundary and potentially another location, access requirement and connection record. That difference belongs in the project scope, not just in a parts list.
Catalog input versus the selected connection drawing
VST’s published FL20-100W record identifies a complete 100W fitting, an AC input range and an LED driver field. Those entries help identify the product under discussion. The actual connection arrangement still belongs to the supplied driver and control version.
For example, a supply-range entry answers which supply the catalog describes. It does not define the purpose of an unidentified extra lead. A product photograph can show where a cable leaves the housing; the applicable connection drawing explains its electrical role. Use each record for the question it can answer.

Separate switching, dimming and color settings
Turning a fitting off and reducing its output
Switching determines whether the intended arrangement operates on or off. Dimming changes output through a supported control function. A purchasing request that says only controlled floodlight leaves this difference unresolved: the user might expect a lower overnight scene while the offered product provides only switching.
The control device and regulating electronics must provide the intended action together. A wall-mounted device with a familiar appearance may be an ordinary switch, an analog dimming control or part of a digital system. Its physical position tells you little about the command it supplies.
A color setting and a control command
Cooper Lighting Solutions’ HALO Outdoor ARFL instructions, document IL51880222, give a useful example. The identified product has remote functions for power, white-light setting and photocell mode, yet the same instructions explicitly identify the luminaire as non-dimmable. A remote is therefore not a sufficient specification for brightness control.
| Required action | Function to identify | Effect on the equipment choice |
|---|---|---|
| Turn the light on and off | The intended switching arrangement | Select equipment that controls the required fitting or group |
| Maintain a lower light scene | The supported dimming function and lower state | A switching-only version cannot supply that scene |
| Choose a white appearance | The available CCT setting and adjustment method | Keep color selection separate from brightness control |
| Operate automatically at night | The relevant daylight or scheduling input and mode | Identify what decides when the lighting should operate |
A photocell, timer and sensor make different decisions
The input that triggers a command
A daylight input concerns the light reaching a sensor. A timer concerns a scheduled event. An occupancy input concerns detected activity. These inputs can support different operating strategies even when they ultimately control the same type of floodlight.
A commercial entrance might need lighting whenever its night schedule is active. A separate service area might need a changed state when occupied. Describe those requirements individually. Otherwise a single automatic setting may be selected for two jobs that need different behavior.
The equipment that acts on the command
The DALI Alliance’s system-role explanation distinguishes input devices, application controllers, control gear and bus power supplies. Inputs provide information; the application controller makes decisions and sends commands; control gear supplies the light source. More than one role can be combined in one product.
This makes a functional drawing useful before detailed electrical design. Draw the input, the decision and the intended lighting response as separate roles. Then identify which actual supplied devices perform them. A sensor symbol alone leaves the decision and output arrangement incomplete.
For instance, a schedule entry can tell an application controller when a group should change. The controller still needs a supported way to command the relevant gear. Showing that relationship helps distinguish missing control equipment from a missing luminaire: both can leave the requested scene unavailable, but they are different purchasing problems.

Read the operating mode with the source instructions
A switch-controlled mode
A switch-controlled mode gives the user a defined way to request on or off. Read what the selected product calls that mode and which other functions remain active. A daylight-controlled fitting can behave differently from an ordinary switched fitting when its automatic mode is enabled.
The ARFL instructions describe switch-activated and dusk-to-dawn operation separately. Their remote settings belong to that identified product. For a different floodlight, use its own supported mode rather than assume that another remote’s buttons or sequence apply.
An automatic daylight mode
In an automatic mode, the installation may be intentionally dark while daylight is available. That is a control response, not necessarily a failed light. The planning question is whether the daylight-controlled behavior suits the task and whether the intended arrangement supports it.
Location matters to the input as well as to the useful beam. A sensor receiving shade or reflected light can encounter a different condition from the open area being illuminated. The applicable device information and site design should address that relationship. There is no universal sensing position or timing value that can be supplied from the word photocell.
What changes when the floodlights need dimming?
A supported analog control path
Some identified products have a separate analog dimming arrangement. In that case, reducing output involves the supported control path and regulating electronics as well as the power supply. It is a different requirement from placing an ordinary on/off device in the project description.
Do not import that arrangement into another manufacturer’s fixture from an illustration. A drawing may be useful for recognizing separate power and control roles while remaining inapplicable to the proposed product’s connections.
A digital controller and its lighting groups
A digital control request also needs an intended system. VST’s FL20 catalog lists DALI and DMX512 options; the selected quotation must identify the version actually offered. A menu of interfaces is not a declaration that one driver or fitting accepts every system.
For a DALI project, retain the roles of the controller, inputs, control gear and communication power in the plan. The exact device arrangement supplies those roles. Its connection, capacity and configuration requirements need their own applicable records.
| Project requirement | Role to provide | Version-specific input |
|---|---|---|
| One group follows a user switch | The intended switching function | The selected fitting and switching arrangement |
| A group runs at reduced output | Supported regulation and a dimming command | The actual driver/interface and required lower behavior |
| Groups respond independently in a digital system | Controller decisions and commands to the intended groups | The supported system, devices and group behavior |

One switch or several lighting groups?
The sources that should change together
Group the lighting by the required behavior. If every fitting should follow the same schedule and output state, one shared command may serve the brief. If some lights must remain at another state, the functional plan needs a way to express that difference.
Imagine a loading doorway beside a perimeter route. During deliveries, the doorway needs its working scene. Later, the loading task ends while the perimeter route retains its separate night requirement. A single undifferentiated command cannot describe both changes unless the intended system provides another supported means of making them.
That is a grouping decision, not a calculation of how many luminaires may be connected to a switch. Electrical ratings and circuit design are separate work. Keeping the questions distinct prevents an early control sketch from being mistaken for an approved circuit layout.
Group names should describe the task clearly enough for the operator to recognize it. Loading doorway and perimeter route are more informative than group one and group two in the early brief. The final system identification can then connect those task names to the equipment and commands used by the installation.
The connection space is part of the installation plan
Housing, cable entry and access
A product can have the required control function and still create an awkward installation if the connection space is inaccessible. Consider the closed enclosure, cable exit, mounting support and movement needed for aiming. The chosen angle should not depend on pulling an external cable tight.
The actual product information identifies the intended connection and mounting arrangement. Its scope can differ from the surrounding work: a body dimension may exclude the bracket or an adjacent enclosure, and a cable length may not describe the full route to the building system.
These are useful procurement questions because they change what is supplied and what remains installation work. Resolve them around a real detail rather than add an unspecified waterproof connector to every drawing. The published FL20-100W entry provides a concrete product starting point; its actual selected version still governs the job.

Turn a two-zone brief into a clear system description
Inputs and the required operating behavior
Consider a hypothetical commercial exterior with a loading group and a separate perimeter group. The loading group should follow the delivery schedule and an intended user command. The perimeter group should follow its own night brief. These are planning inputs, not a description of a completed VST project.
First write each group’s required change. Next identify which input initiates it and which controller or switching function acts on it. Finally identify the complete fitting and the regulating/control version that can produce the response. This sequence exposes a missing function without specifying a field connection.
The chosen functions and the unresolved drawing detail
| Zone | Required behavior | Functional choice | What remains specific to the offered system |
|---|---|---|---|
| Loading doorway | Follow the delivery schedule and intended user command | A separately controllable loading group | The actual switching/controller arrangement and fitting version |
| Perimeter route | Follow its separate night requirement | A distinct daylight or scheduled operating function | The intended input, mode and commanded lighting state |
| Both zones | Preserve independent changes when the jobs differ | Reject an undifferentiated shared command that cannot do so | The applicable device and connection drawings for the chosen architecture |
The result is a usable system description: two tasks, separate required commands and identifiable equipment roles. The next design drawing can now answer the remaining product-specific questions. It is more informative than a request for two floodlights with control, while avoiding a guessed wiring recipe.
Use the floodlight specification guide for the other fields that change product selection. Keep this plan focused on the power and control relationships that the drawing must explain.