Logistics lighting supply
Warehouse lighting planned around your racks and work zones
- High-bay fixtures for tall storage spaces
- Linear battens for lower work zones
- Outdoor floodlights for covered loading approaches
- Layout support using your rack and task information
Working surfaces
Design for the racks as well as the floor
Rack geometry
Measure aisle width and rack height. Mark which shelf faces need readable labels so the calculation shows whether light reaches the picking locations.
Task separation
Mark receiving, packing, inspection, and travel areas on the plan. Calculate their tasks separately from the light needed for bulk storage.
Maintenance access
Check whether a lift can reach each fitting with the racks loaded. This affects mounting positions and how you plan spare units.

Logistics project support
Choose fittings from the rack and work-area plan
Calculation from the rack plan
Ask VST for a DIALux proposal based on rack height, aisle width, mounting positions and the selected optic. Request separate results for aisle floors, vertical picking faces and packing benches, with the agreed lighting targets and assumptions recorded.
Separate zone quantities
List aisle lights, packing fittings, and loading fixtures separately. The site team can then receive the order and allocate each model to its zone.
Sample configuration control
Agree the trial fixture’s lens, driver, and light color. Retain that configuration as the reference when you release the rest of the warehouse order.
Shipment coordination
Tell VST the installation phases and receiving constraints. Discuss packing and order releases around what the site can handle at each stage.
Layout scope
What warehouse lighting needs to illuminate
Fixture shortlist
Fixtures for storage, packing, and loading
40W packing-area batten
200W loading-area floodlight
Layout essentials
Information for the layout and installation

Surface-based design
Include vertical shelf faces and packing planes in the calculation. Check whether the distribution reaches tasks that racks and stored goods can obscure.

Mounting clearance
Keep high-bay bodies and supports clear of sprinklers, racks, and handling equipment. Check those clearances when setting positions on the mechanical layout.

Occupancy zoning
Select driver controls and sensor coverage for the activity in each zone. The occupied areas determine where sensing is useful and how it should operate.

Receiving identification
Identify the model for each zone on the order list and cartons. This helps receiving staff allocate the fittings when several areas are supplied together.
High-bay detail
The high-bay source, lens, and housing

Emitting surface
High-bay LED array

Distribution control
High-bay lens

Heat dissipation
High-bay finned housing
Working with VST
Get to know the warehouse supply contact
VST company introduction
Get to know VST before discussing the warehouse package. Bring the rack plan and work zones to that conversation. Use the matching photometric files and model data to calculate the layout for the configurations you are considering.
Customer feedback on cooperation
Watch a customer perspective on working with VST. For your logistics project, agree fixture quantities, zone identification, and release dates against the site schedule. Judge the proposed warehouse layout from its own data and calculations, with the customer video providing general cooperation background.
Operational zones
Lighting for warehouse storage and handling

Tall rack storage

Open receiving areas

Packing workstations

Covered loading docks

Mezzanine picking areas
Share the rack layout
Send the rack plan or aisle photos
Published fixture data
Published models for the logistics building
| Model | Power | Output / efficacy | Input (VAC, 50/60Hz) | IP |
|---|---|---|---|---|
| VST-HBL-240WF | 240W | 36,000 lm | 100–277V | IP65 |
| VST-HBL-300WF | 300W | 51,000 lm | 100–277V | IP65 |
| VST-HBL-500WF | 500W | 80,000 lm | 180–305V | IP65 |
| VST-HBL-100WF | 100W | 15,000 lm | 100–277V | IP65 |
| VST-HBL-150WF | 150W | 22,500 lm | 100–277V | IP65 |
| VST-HBL-200WF | 200W | 30,000 lm | 100–277V | IP65 |
| Model | Power | Output / efficacy | Input (VAC, 50/60Hz) | IP |
|---|---|---|---|---|
| VST-STF-60-20W | 20W | 2,600 lm | 220–240V/100–277V | IP65 / IP66 |
| VST-STF-120-40W | 40W | 5,200 lm | 220–240V/100–277V | IP65 / IP66 |
| VST-STF-150-50W | 50W | 6,500 lm | 220–240V/100–277V | IP65 / IP66 |
| Model | Power | Output / efficacy | Input (VAC, 50/60Hz) | IP |
|---|---|---|---|---|
| VST-FL20-50W | 50W | 7,500 lm | 100-277V | IP65 |
| VST-FL20-100W | 100W | 15,000 lm | 100-277V | IP65 |
| VST-FL20-150W | 150W | 22,500 lm | 100-277V | IP65 |
| VST-FL20-200W | 200W | 30,000 lm | 100-277V | IP65 |
| VST-FL20-250W | 250W | 37,500 lm | 100-277V | IP65 |
| VST-FL20-300W | 300W | 45,000 lm | 100-277V | IP65 |
| VST-FL20-400W | 400W | 60,000 lm | 100-277V | IP65 |
| VST-FL20-500W | 500W | 75,000 lm | 100-277V | IP65 |
| VST-FL20-600W | 600W | 90,000 lm | 100-277V | IP65 |
Cooperation feedback
Feedback on logistics orders
Program terms
Arrange quantities and release dates
Before the final layout
Questions before ordering warehouse lighting
| Operating pattern | Design implication |
|---|---|
| Frequently occupied work zone | Avoid unnecessary repeated switching |
| Intermittent rack aisle | Assess occupancy coverage and dimming |
| Daylit receiving area | Evaluate daylight response with occupancy |