Outdoor Project Supply
LED Flood Light Manufacturers for Controlled Area Coverage
- 50W to 600W rectangular flood-light platforms
- Optics and brackets selected for site geometry
- Model files, samples, and inspection planning
Site-Based Specification
Turn the Area-Lighting Task into a Fixture Requirement
Start with the Area
Define the surface, task, mounting point, obstructions, boundaries, and required coverage before choosing power.
Select the Optics
Compare lens or glass-cover routes, distribution, spill control, tilt, and fixture spacing on a site basis.
Verify the Mounting
Review bracket geometry, aiming range, fasteners, structure, cable routing, wind exposure, and service access.
Confirm Outdoor Details
Tie sealing, materials, coating, surge, driver, controls, and operating conditions to the quoted model.
Plan Project Delivery
Coordinate quantities, batch labels, cartons, mounting accessories, documents, and delivery sequence.

Flood-Light Manufacturing
Compare the Factory Through Project Controls
Power Family Coverage
VST's published rectangular range covers compact 50W units through 600W project platforms. This provides a model shortlist when comparing LED flood light manufacturers for area size and mounting height.
Optical Selection
Model-level lens and cover options can be reviewed against reach, coverage, spill, glare, and fixture layout.
Thermal Verification
Housing, heat-sink geometry, driver loading, ambient conditions, and operating time are considered together.
Outdoor Detail Review
Bracket, cable entry, seals, finish, surge, protection scope, and access can be clarified before sample approval.
Project Documentation
As an LED flood light factory, VST can identify which drawings, datasheets, reports, certificates, packing information, and inspection records apply to the quoted model.
Flood-Light Selection
What Changes Across an LED Flood Light Range
Outdoor Flood-Light Platforms
Choose a Power and Optics Starting Point
150W Industrial Yard Flood Light
250W Sports and Area Flood Light
400W High-Mast Flood Light
600W Major-Site Flood Light
Decision Controls
Checks Before Approval
Beam Planning
Choose distribution and aiming from area geometry, mounting point, task, spill limits, and spacing.
Outdoor Construction
Confirm model-specific sealing, cable entry, materials, finish, protection scope, and conditions.
Thermal Path
Relate LED loading, housing fins, driver position, ambient temperature, and duty cycle.
Bracket Alignment
Check aiming range, bolt positions, structure, fasteners, wind exposure, cable clearance, and access.
Flood-Light Construction
How the LED Face, Heat Sink, and Bracket Work

Primary Light Source
LED Array

Thermal Structure
Rear Heat Sink

Mechanical Interface
Aiming Bracket
Flood-Light Supplier Context
A Company View and a Customer View
VST Company Overview
The overview supplies company context for an outdoor-lighting program. It does not replace flood-light photometric data, protection evidence, or mounting review.
Customer View of Project Coordination
This approved customer video adds commercial context but does not establish flood-light output, outdoor durability, or results at a named site.
Outdoor Area-Lighting Applications
Connect the Fixture to the Site Geometry

Building Perimeters and Entrances

Parking Areas and Service Yards

Loading Docks and Industrial Aprons

Sports Training Fields

Ports and High-Mast Infrastructure
Bring the Site Data
Request a Flood-Light Platform and Optics Review
Technical Review
Flood-Light Technical Boundaries
| Model | Power | Luminous flux | Dimensions | Weight |
|---|---|---|---|---|
| VST-FL20-50W | 50W | 7,500 lm | L317 x W268 x H63.5mm | 2.5kg |
| VST-FL20-100W | 100W | 15,000 lm | L351 x W282 x H63.5mm | 3.0kg |
| VST-FL20-150W | 150W | 22,500 lm | L392 x W333 x H63.5mm | 4.3kg |
| VST-FL20-200W | 200W | 30,000 lm | L448 x W333 x H63.5mm | 5.2kg |
| VST-FL20-250W | 250W | 37,500 lm | L515 x W383 x H66.5mm | 7.0kg |
| VST-FL20-300W | 300W | 45,000 lm | L515 x W383 x H66.5mm | 7.8kg |
| VST-FL20-400W | 400W | 60,000 lm | L577 x W483 x H68mm | 11.0kg |
| VST-FL20-500W | 500W | 75,000 lm | L577 x W483 x H68mm | 12.0kg |
| VST-FL20-600W | 600W | 90,000 lm | L628 x W535 x H70mm | 16.0kg |
| Parameter | Published value |
|---|---|
| Efficacy | 150 lm/W |
| Input voltage | AC100-277V, 50/60Hz |
| Protection | IP65; IK08; 6kV surge standard, 10kV optional |
| Optics | 30ยฐ/60ยฐ/90ยฐ PC lens; 120ยฐ glass cover |
| CCT & CRI | 3000K/4000K/4500K/5000K/5700K/6500K; Ra โฅ70, Ra โฅ80 optional |
| Dimming | DALI / DMX512 |
| Lifetime / warranty | 50,000 hours / 5 years |
Outdoor Project Feedback
Comments on Flood-Light Project Coordination
Working with VST
Outdoor Fixture Cooperation Questions
Product Questions
LED Flood-Light Project Questions
| Input | Decision affected |
|---|---|
| Mounting height and setback | Reach and aiming angle |
| Area width and depth | Spread and fixture count |
| Boundaries and windows | Spill and glare control |
| Task criteria | Output and uniformity |
| Area | Evidence |
|---|---|
| Housing and cover | Joints, seals, and material |
| Cable entry | Gland and installation method |
| Electrical protection | Driver, surge, and earthing |
| Environment | Temperature, corrosion, cleaning |



