Industrial project lighting
Industrial high bay LED lights matched to your working zones
- Six published platforms span 100W to 500W for different lighting duties.
- VST can prepare a DIALux layout using your working planes and obstructions.
- Specify controls and mounting details before arranging a representative sample.
Start with the building
Choose lighting for each part of the facility
Record the working plane
Floor lux alone may miss a vertical inspection face or a raised assembly bench. Mark the surfaces on which visibility matters.
Locate physical obstructions
Cranes, ducts and tall equipment can interrupt light paths. Include their positions when assessing a proposed fixture grid and access route.
Separate operating zones
An infrequently occupied transfer bay can need different controls from a continuously staffed line. Group fixtures around actual operating patterns.

Engineering support
Engineering support for industrial high bay LED lights
Photometric planning
VST's lighting-design team can model working areas in DIALux so you can examine the distribution before deciding how many fixtures to order.
Relevant sample measurements
VST can use integrating-sphere and IES testing to evaluate total output and distribution. Request data for the sample configuration you intend to install.
Coordinated technical input
Electrical, structural and lighting engineers can work on the same specification, addressing the suspension, power supply and optics needed for your installation.
Project supply coordination
Discuss packing and shipment timing with VST so the lighting delivery fits your installation schedule.
Selection principle
Plan the distribution of industrial high bay LED lights
Published VST range
Compare six industrial platforms
150W configurable platform
200W production platform
240W tall-space platform
300W high-output platform
500W large-hall platform
Specification support
Support for layout, production and delivery
Layout development
Send the building geometry and task requirements. A lighting simulation lets you assess fixture positions and distribution before settling the layout.
Production checks
VST checks incoming materials, work in progress, finished products and outgoing goods against the order specification.
Configuration support
Choose the CCT, controls, finish and identification for your platform. VST will assess the requested combination against the model and project requirements.
Export packing
Protective inner packing and outer cartons can be planned around the luminaire. Include handling and destination requirements in the packing discussion.
Inside the luminaire
Components that influence the lighting result

Light generation
LED light source

Heat management
Die-cast aluminum housing

Light distribution
PC lens
Working with VST
Meet the company behind the order
Company introduction
The introduction explains VST's business. For an order covering a whole building, ask how the team will handle lighting design, technical questions and production across the selected models.
Customer cooperation
The customer video covers the experience of working with VST. Agree your own approval milestones and delivery sequence, particularly when different zones use different models or have separate installation dates.
Industrial applications
Match the fixture to the activity below

General manufacturing

Pallet storage

Covered goods transfer

Vehicle maintenance halls

Utility equipment buildings
Discuss the site
Send the building outline and lighting task
Technical comparison
Published specifications and project preparation
| Model | Rated power | Selectable settings | Output at full power | Input | Beam | Body |
|---|---|---|---|---|---|---|
| VST-HBL-100WF | 100W | 100 / 80 / 60W | 15,000 lm (150lm/w) | 100–277V AC 50/60Hz | 90° / 120° | Φ238 × H105 mm |
| VST-HBL-150WF | 150W | 150 / 120 / 100W | 22,500 lm (150lm/w) | 100–277V AC 50/60Hz | 60° / 90° / 120° | Φ255 × H162 mm |
| VST-HBL-200WF | 200W | 200 / 150 / 120W | 30,000 lm (150lm/w) | 100–277V AC 50/60Hz | 60° / 90° / 120° | Φ300 × H176 mm |
| VST-HBL-240WF | 240W | 240 / 200 / 150W | 36,000 lm (150lm/w) | 100–277V AC 50/60Hz | 60° / 90° / 120° | Φ365 × H176 mm |
| VST-HBL-300WF | 300W | 300 / 220 / 190W | 51,000 lm (170lm/w) | 100–277V AC 50/60Hz | 60° / 90° / 120° | Φ385 × H182 mm |
| VST-HBL-500WF | 500W | 80,000 lm (160lm/w) | 180–305V AC 50/60Hz | 30° / 60° / 90° / 120° | Φ490 × H208 mm |
| Shared parameter | Published value |
|---|---|
| Power Factor | >0.95 |
| LED Chip | Philips Lumileds |
| LED Driver | Sosen |
| CCT & CRI | 3000K / 4000K / 5000K / 5700K / 6500K; CRI >80 |
| Optical cover | PC lens |
| Housing Material | Die-cast aluminium |
| Ingress Protection Rating (IP Rating) | IP65 |
| Impact Resistance Rating (IK Rating) | IK08 |
| Total Harmonic Distortion (THD) | <15% |
| Surge Protection | 6kV |
| Dimming Option | 0-10V / 1-10V / PWM / TRIAC / ZigBee / Sensor |
| Working Temperature | -40°C to +60°C |
| Lifetime | 50,000 hours |
| Warranty | 5 Years |
Cooperation feedback
What customers value in the working process
Order planning
Questions about a multi-model order
Before specification
Resolve the remaining project boundaries
| Control route | Information to provide |
|---|---|
| Analog dimming | Controller model, wiring and required off behavior |
| Sensor operation | Detection zone, mounting height and occupancy pattern |
| Wireless control | System, gateway and operating requirements |


