EXTERIOR LED CHANNEL
Exterior LED Channel for Covered Entrances and Canopies
- Flat WPT forms sit close to a mounting plane.
- Rounded WPR covers soften the visible line.
- WPT2020 aims light out of a protected corner.
Product overview
Where exterior LED channel fits into your lighting design
Exposure first
Record whether the line sits under a canopy, beside an opening or in direct weather.
Cable-entry risk
A protected housing still needs a cable route that avoids collecting water at its end.
Sealing evidence
Ask what completed assembly was tested before relying on an IP description.
Maintenance access
Decide how a strip or cover will be reached without damaging the surrounding finish.

VST supply support
How VST supports exterior LED channel selection
Published forms
VST lists flat, rounded and corner forms in its IP65 profile range. The drawings let you narrow the housing before setting the strip and end treatment.
Assembly discussion
A cover that appears seated may still leave a weak cable exit or end joint. VST can examine those details with the proposed strip assembly.
Site-specific review
The canopy shape, runoff route and cleaning method determine where a channel can be fixed. Put them on the drawing before choosing a form.
Sample observation
A short mockup shows the direction of the light and the visible cover from the approach. It also gives the team an assembly to inspect.
Selection basis
What defines exterior LED channel
Configuration references
Compare exterior LED channel forms
WPT1813: Deeper flat channel
WPT2020: Directional corner line
WPR1813: Rounded visible face
WPR1809: Low Rounded Channel
Practical checks
Details that protect the exterior LED channel decision
Site exposure
Show the route of rain and runoff on the installation drawing. It helps identify where exposed joints may face wind-driven moisture.
Cover joint
Check the joint between diffuser, end treatment and cable outlet. The completed assembly can then be assessed against the actual exposure.
Canopy mockup
A sheltered-site mockup exposes unwanted reflections or trapped water paths. This makes drainage and cover appearance visible before repeated installation.
Matched end parts
Keep sealing parts identified with their matching lengths during dispatch. A matching end set is easier to locate during work under a canopy.
Component decisions
Housing, Cover and Cable Details for Exterior Runs

Housing
Flat Aluminum Housing

Optical component
Diffuser Cover

Light source
LED Strip Width

End detail
End Cap and Cable Exit
Company perspective
Working with VST on protected lines
VST lighting operation
The company film introduces VST's broader lighting work. For a channel under a canopy, send the team the site drawing, strip choice and cable-entry plan. A housing can then be discussed without assuming that the whole light carries the profile category's IP label.
Working relationship
The customer video speaks to cooperation with VST, not to the protection level of a particular model. Use the project sample and test scope to settle the exterior assembly you intend to install.
Application guide
Choose exterior LED channel by installation task

Covered entrances

Canopy corner accents

Protected sign surrounds

Service corridors

Equipment perimeter lines
Request a profile review
Specify the right exterior LED channel for your project
Technical planning
Exterior LED channel specifications and installation
| Model | Section | Strip width | Mounting | Cover options | Standard length | Listed accessories |
|---|---|---|---|---|---|---|
| WPT1809 | W18mm ร H9mm | โค11 mm | Flat surface | PC/PMMA | 2m | clips / end caps |
| WPT1813 | W18mm ร H13mm | โค11 mm | Flat surface | PC/PMMA | 2m | clips / end caps |
| WPT2020 | W20mm ร H20mm | โค11 mm | Corner | PC/PMMA | 2m | clips / end caps |
| WPR1813 | W18mm ร H13mm | โค11 mm | Rounded surface | PC/PMMA | 2m | clips / end caps |
| WPR1809 | W18mm ร H9mm | โค10 mm | Rounded surface | PC/PMMA | 2m | clips / end caps |
Working with VST
Supply questions for exterior LED channel
Product questions
Practical exterior LED channel decisions
| Form | Models | Selection use |
|---|---|---|
| Flat | WPT1809 / WPT1813 | Low face on a straight plane |
| Rounded | WPR1809 / WPR1813 | Softer visible cover line |
| Corner | WPT2020 | Diagonal light from a protected angle |

