VST Lighting Logo

Local outdoor tasks

50W LED Flood Light for Compact Exterior Lighting

Choose a 50W LED flood light around the detail you need to illuminate.
  • 7,500 lm published output from the compact FL20-50W.
  • Lens or glass-cover builds for different local tasks.
  • Gray and black housing choices.
  • Practical support for mounting, light color and sample selection.

Local outdoor tasks

Light the entrance without dominating the surroundings

For a small commercial exterior, start with the area that needs more light. Check the target surface and nearby sightlines before deciding where to mount the fixture.
A 50W LED flood light directs light toward an entrance, sign or small working area. Even at this power, a fixture near eye level can be uncomfortable to look at. Identify the surface you want to light and a mounting position that lets the beam fall onto it. VST can discuss the body and optical options from a photo, helping you decide whether this model fits the task before requesting a sample.
✓

A defined target

Identify the doorway, sign face or working surface. With a clear target, you can choose a beam that puts light where it is needed.

✓

Nearby sightlines

Check the view from the pavement and adjacent windows. The final aim should respect those positions as well as the area being illuminated.

✓

Limited mounting space

Use the published body dimensions when looking around a canopy or conduit. The bracket also needs practical access for adjustment and secure fixing.

Small-project support

Get the details you need for a small exterior project

As a 50W LED flood light manufacturer, VST can help turn your local lighting requirement into a product specification.
✓

Accessible starting information

Send a photo and a short description of what needs lighting. Our team can identify which additional measurements would affect your choice of fixture.

✓

Light-color discussion

Discuss CCT and color rendering in relation to the surface you want to light. Choose an appearance that suits the entrance or display without assuming it will improve every visibility task.

✓

Engineering availability

VST's team includes electrical and structural engineering expertise. Questions about control interfaces or a constrained bracket position can be directed to the relevant discipline.

✓

Sample-based decisions

A sample lets you evaluate the proposed fixture in its intended context. VST's testing capability can also support the optical questions that need measurement rather than a photograph.

Category scope

A compact floodlight is still a directional luminaire

The 50W LED flood light category describes input power. Check sensor, power-system and coverage requirements separately.
The complete fixture has a light source, optical front and housing with a mounting bracket. Choose it according to the target's distance and width, the available supply and the intended controls. A narrow local task may need a different beam from a nearby open landing, even at the same rated power. The FL20-50W has published lens and glass-cover options for these choices. Specify any sensor or solar requirement explicitly: the power category alone does not establish an integrated detector, solar supply or a preset area of coverage.

Choose the front construction

50W LED Floodlight Configurations for Local Tasks

Your 50W LED flood light supplier can quote these two documented versions separately.

Glass-cover build

A 120ยฐ configuration offers broader distribution for a nearby landing or small exterior area, subject to sightline assessment.
View Product

Useful construction details

Check the construction and supply details

Choose the physical and packing details that matter for your installation.

Optical alternatives

The listed front options allow a choice between lens-directed light and the broad glass-cover configuration within the same 50W family.

Finned rear housing

Air can move around the exposed aluminum rear surface when adequate clearance is maintained. Avoid hiding the fixture inside a decorative box.

Outdoor-rated body

The model lists IP65 protection for the enclosure. Install the supply connection with protection suitable for its own location and exposure.

Private-label support

As a 50W LED flood light OEM supplier, VST supports agreed product labels and packaging that identify the supplied configuration.

Visible components

Inspect the parts that affect light, cooling and aim

The source, back and bracket answer different installation questions.

Light-producing element

SMD3030 LED source

SMD3030 packages behind the optics produce the light in this model. Their selected CCT affects how the illuminated surface looks, and the task determines the color-rendering requirement. A sign face may need different treatment from an access landing. Request data for the complete version you are considering. The LED package designation alone cannot replace optical measurements when you compare the proposed fixture with an alternative.

Cooling structure

Aluminum back

Heat leaves the fixture through its aluminum rear structure. A narrow recess under a canopy may look convenient, but it can restrict airflow. Check that air can reach the back and that the mounting surface leaves it unobstructed. Allow clearance around the body as well as space for the body itself when deciding whether the fixture fits the proposed position.

Positioning component

U-shaped yoke

The yoke lets you aim the compact fixture at the selected surface. It needs a sound fixing substrate, access for the anchors and room to adjust the pivots. Check that movement before routing the cable so aiming does not pull on the connection. Assess the mechanical support even for a small fixture, and check old anchors before using existing wall holes.

Working with VST

Company and Customer Videos

A first look at VST and the experience of cooperation.

Meet VST before choosing a supply route

Use this introduction to get to know VST before discussing your lighting requirement. The product information will help you prepare questions for that conversation. The video does not demonstrate the light level or suitability of a fixture at your particular entrance or sign.

A customer perspective on communication

Hear about a customer's cooperation with VST. For your exterior task, use the site details and selected sample to make the product choice. This feedback does not establish a particular result for the FL20-50W, and supply details still need to be agreed in writing.

Application planning

Small outdoor areas with a defined purpose

50W LED floodlights suit consideration where the local lighting task is clearly defined.

Shop entrance landings

Consider a 50W LED flood light for the landing outside a small commercial entrance. Check the door swing, pedestrian approach and nearby windows when deciding on position and beam. VST can discuss a compact version and light color for you to assess against the entrance materials and surrounding sightlines.

External sign faces

An external sign needs light across its face without a distracting view of the fixture or beam. Check the sign dimensions, finish and available setback, including limits on light beyond the edges. Our team can assess the proposed mounting position and suggest an optic to try in a sample.

Service doors

A rear service door needs light on the threshold and handling area when deliveries occur after dark. Describe overhangs, steps and where a trolley or parked vehicle could obstruct the light. VST can help choose a distribution and provide the mechanical information needed to assess the available wall position.

Courtyard access steps

Steps in a commercial courtyard need visible changes in level without a direct bright source along the normal walking sightline. Identify the step arrangement, wall position and neighboring surface reflectance before fixing the aim. We can assist with the fixture choice and discuss the information your designer needs for the access-lighting assessment.

Outdoor utility stations

A small outdoor utility station may need local light for reading controls or carrying out routine service work. Describe the working distance and surroundings, and identify any special environmental classification for that location. VST can assess the task and supply fixture details for the site's technical team to check.

A simple starting point

Show us the surface you want to light

Send a site photo, approximate mounting height and quantity. We can help choose a 50W LED flood light and identify any further details needed to prepare the quote.

Technical information

FL20-50W Specifications and Implementation

Check the compact model and practical connection steps before selecting a build.
Specification VST-FL20-50W
Model Number VST-FL20-50W
Rated Power 50W
Luminous Flux 7,500 lm (150 lm/W)
Input Voltage AC 100-277V, 50/60Hz
Power Factor >0.9
Surge Protection 6kV standard, 10kV optional
CCT & CRI 3000K, 4000K, 4500K, 5000K, 5700K, 6500K, Ra โ‰ฅ70; Ra โ‰ฅ80 optional
Beam Angle PC lens for 30ยฐ/60ยฐ/90ยฐ; Glass cover for 120ยฐ
LED Chip SMD3030
LED Driver ZH-LVP
Dimming Options DALI, DMX512
IP Rating IP65
IK Rating IK08
Material Aluminum, PC, tempered glass
Body Color Gray, Black
Operating Temperature -30ยฐC to +50ยฐC
Dimensions L317 x W268 x H63.5 mm
Weight 2.5kg
Lifetime 50,000 hours
Warranty 5 Years
Choose the listed optics, housing finish and light color, then describe your labeling and packing needs. VST can assess additional requirements as your 50W LED flood light OEM supplier and quote the scope and cost separately from the standard build.
VST assembles the selected parts to the agreed specification, then carries out production and outgoing checks. Labels identify the version ordered, particularly where fixtures with different optics share a shipment.
Use a qualified electrician for the supply connection. Isolate power, check the circuit, secure the yoke to suitable anchors and protect the connection. Maintain rear clearance and adjust the fixture toward its target. Assess nearby sightlines after dark before accepting the final aim.

Cooperation feedback

A straightforward first order

Customers describe the support they appreciated.
I sent a photo of the entrance and received a clear list of the details you needed. That was a helpful way to start.
Alice RowanProject Coordinator, Commercial fit-out business

Order planning

Start and schedule your order

Samples, quantities and payment explained directly.
01

Yes, a sample is available for evaluating your proposed position. As your 50W LED flood light supplier, VST will identify the selected configuration and sample charge in the quotation. Any credit toward a later bulk order is agreed with VST beforehand rather than treated as a free-sample promise.
02

For lower-power fixtures such as this category, 100 pieces is a general planning starting point. The minimum for a particular finish, label or custom construction is stated in the quotation. It should not be assumed to apply unchanged to every version.
03

A label change and a housing redesign are different scopes. VST supports private labels and custom packaging; a deeper mechanical change may require tooling. Provide the desired result so the quotation can identify the work and any associated charges accurately.
04

Typical production for regular products is 2 to 3 weeks. Light customization is generally around 3 to 4 weeks and extensive customization around 4 to 6 weeks. These are production planning ranges, with transit and the actual order schedule handled separately.
05

Sample orders require full payment in advance through PayPal, Western Union or bank transfer. Bulk orders normally use bank transfer with 30% paid as deposit and 70% before shipment. The applicable invoice records the agreed arrangement.
06

Provide a brief explanation and photos or video showing the issue with the VST product. Replacement support can be discussed after assessment, either separately or with a later shipment. Do not discard the product identification needed to connect the issue with the order.

Product questions

Check the power and operating arrangement

Check the power source and operating method before selecting a 50W LED flood light for a local task. These questions address the fit between a complete mains luminaire and the accessories or functions needed at the location.

An integrated motion detector is not established for the listed FL20-50W. If automatic operation is needed, describe the detection area and existing system before ordering. An external detector must have a suitable LED-load rating and be assessed with the selected driver and circuit.

The published configuration accepts AC 100 to 277V, so it is not a direct 12V battery light. A low-voltage or solar requirement needs a separately assessed product and power system. Do not infer a compatible supply from the small housing or nominal 50W rating.

Describe the sign rather than guessing the beam first.
Face Width, height and material
Position Available setback and fixing surface
Boundary Viewers and nearby windows
A photo showing all three makes the intended result easier to discuss.

The provided model information does not establish a region-specific plug or a particular cable length. State the required connection arrangement in your inquiry. A compatible lead and termination should be identified in the supply scope, rather than assumed from an application photograph.

The shown yoke is a mounting component, not proof of an approved portable work-light stand. For a fixed installation, use a suitable secured support and protected electrical connection. If you need a movable fixture, describe that requirement so the complete support and cable arrangement can be evaluated.
Inquiry Now