VST Lighting Logo
t8 led tube with rotate end cap
t8 led tube with G5 pin
waterproof t8 led tube lights
integrated t8 led tube
t8 led tube VST-T8-970-15W
t8 led tube light with G5 pin
t8 led tube with rotate end cap
t8 led tube with G5 pin
waterproof t8 led tube lights
integrated t8 led tube
t8 led tube VST-T8-970-15W
t8 led tube light with G5 pin

970mm T8 LED Tube Light for Custom OEM Sourcing

The VST-T8-970-15W is a 970mm, 15W T8 LED tube for custom fixture replacement, OEM integration, and commercial lighting projects where standard tube lengths do not fit. It offers 150lm/W efficiency, 50,000hrs lifespan target, AC85V-265V input, a constant current internal driver, and a 160° beam angle. The aluminum + PC housing supports heat control, while IP20/IP65 options can be discussed by project requirement. VST Lighting helps buyers review CCT, CRI, PC cover, wiring, and structural details with experienced engineers and testing validation, reducing uncertainty during sample development and bulk sourcing.

Key Advantages

  • 970mm custom length supports OEM fixtures and legacy housings that standard tubes cannot fit.
  • 15W power at 150lm/W gives efficient output for special-length commercial linear lighting.
  • AC85V-265V input supports project flexibility across different electrical environments and regions.
  • Aluminum + PC structure helps manage heat and appearance in integrated product designs.
  • VST can review CCT, CRI, wiring, PC cover, and structure changes with engineering input.
  • Integrating sphere and thermal checks support truthful specification control before bulk production.
  • Flexible MOQ discussion helps OEM buyers test special-length demand with lower sourcing pressure.

Mounting Method

Surface Suspended

Dimming Control

Non-dimmable TRIAC 0-10V DALI Sensor

Technical Specifications

Parameter Value
Power 15W
Luminous Efficiency 150lm/w
Lifespan 50,000hrs
Input Voltage AC85V-265V 50/60Hz
Power Factor >0.92
Color Temperature 2700K-7000K
CRI > 80
Beam Angle 160°
LED Driver Constant Current Internal
Dimension D28*970mm
Material Aluminum + PC
PC Type Clear, Frost
Lamp Base G13 or G5
IP Rate IP20 IP65 optional
Working Temperature -20°C~+50°C)
Work Humidity 10%-90% RH

Product Overview

The VST-T8-970-15W is a 970mm T8 LED Tube Light for project buyers and OEM integration teams that cannot rely on standard catalogue lengths. At 15W, it serves custom fixture replacement, product integration, display systems, equipment lighting, and commercial linear lighting designs where the tube must fit a defined structure instead of forcing the structure to fit the tube.

This model delivers 150lm/W luminous efficiency, AC85V-265V 50/60Hz input, >0.92 power factor, a constant current internal driver, and 160° beam angle. The 50,000hrs lifespan target helps reduce maintenance planning for repeat installations. Aluminum + PC construction supports heat management and mechanical stability, while clear or frosted PC options help match the optical effect required by the project.

For a procurement manager, the main issue with customized LED tube light sourcing is often communication. A supplier may accept the order but fail to understand mounting limits, wiring space, brightness targets, or future design revisions. VST Lighting works as a technical partner for these cases. Our engineers have around 9 years of hands-on LED lighting engineering experience and use integrating sphere testing, thermal verification, and aging racks to validate performance before bulk production.

The 900mm T8 LED tube is a closer fit for shorter housings. Check the mounting space and electrical connection before selection.

The 970mm T8 LED tube is suitable for OEM LED tube supplier programs, retrofit projects with unusual fixture lengths, and product companies integrating lighting into equipment or retail systems. VST can support CCT discussion, CRI adjustment, PC cover selection, structure review, wiring preferences, IP20/IP65 options, export packaging, and market-specific certification confirmation by SKU. This gives buyers a practical path from sample approval to repeatable commercial supply.

Application Fit

Best For

OEM fixture integration|Custom retrofit|Display systems|Equipment lighting

Compatible Applications

970mm T8 LED tube for OEM fixture integration|custom retrofit|display system lighting|equipment lighting|special length replacement

Customization Options

Tailor this product to your project or integration requirements.

Support CCT, CRI, PC cover, structure, wiring, base, labeling, packaging and parameter discussions with engineering review, sample feedback, integrating sphere testing, thermal verification and practical communication for OEM/ODM or project needs.

Supply & Commercial Assurance

Minimum Order Qty

120

Lead Time

7 days for samples; 15~25 days for bulk orders depending on quantity, customization, material availability, and order schedule.

Sampling Support

Support sample orders; sample cost can be refunded after confirmed bulk order.

Supply Stability

Stable supply is supported, and stock can be discussed for key partners based on forecast and cooperation plan.

Compliance & Certifications

Certifications

CE RoHS UL

Related Content

Resources

common LED installation mistakes

Common LED Installation Mistakes in Commercial Projects

Common LED installation mistakes usually come from weak planning, not from the light source itself. In commercial projects, the main risks are wrong voltage selection, poor polarity control, undersized drivers, excessive cable length, weak mounting, and missed heat or waterproofing requirements. Fixing these early protects safety, reduces rework, and keeps the installation on schedule. A practical rule is simple: confirm the driver, wiring, mounting, and environmental conditions before the first fixture is fixed in place. If you install LED strip, linear light, or other low-voltage LED systems without checking load, current, dimming method, and IP rating, you will often see flicker, dim ends, heat buildup, or premature failure. Quick Installation Answer Power: Match the driver output voltage to the LED load, and keep a 20% load margin for stable operation and cooler running. Wiring: Verify polarity before energizing low-voltage LED strip, especially on long runs with multiple connection points. Voltage drop: Limit cable length or increase cable gauge when the run is long, because low voltage at the load causes dim ends and color shift. Mounting: Use a clean, flat, dry surface or an aluminum profile when heat dissipation and alignment matter. Dimming: Confirm the dimmer type before installation, since PWM, 0-10V, and TRIAC systems are not interchangeable. Waterproofing: Use the correct IP-rated connector, seal, and enclosure for wet or outdoor zones. Testing: Energize the system before final close-up so you can catch flicker, heat issues, or loose terminations early. Key Installation Checks Confirm the LED voltage, total wattage, and current before selecting the LED driver or power supply. Check the total cable length from driver to load, not just the visible fixture length. Verify the mounting surface, fixing method, and access for future maintenance. Confirm whether the installation area needs an aluminum profile, thermal pad, or airflow for heat dissipation. Check polarity, connector type, and splice method before energizing the circuit. Confirm the dimming method and control signal type if a dimmer or controller is specified. Confirm the IP rating and waterproofing method for damp, outdoor, or washdown locations. Review local electrical code and site safety rules before hardwiring or connecting to mains voltage.

May 23, 2026

LED lighting mismatch

How to Avoid LED Lighting Mismatch in Projects?

LED lighting mismatch happens when luminaires, drivers, controls, or installation conditions do not align, so the project does not perform as specified. The short answer is simple: avoid mismatch by matching voltage, wattage, current, CCT, CRI, dimming method, and installation environment before you order or install. That matters because even a small spec gap can create color shift, flicker, overload, uneven brightness, or failed commissioning. “If the electrical and optical parameters are not matched at design stage, the field result will rarely match the sample.” In practical terms, LED lighting mismatch affects specification accuracy, installation efficiency, maintenance risk, compliance, and total cost. It is not only a product issue. It is a system issue that includes the driver, the load, the control method, and the real site conditions.

May 23, 2026

Ready to Source or Customize?

Tell us your project specs or integration requirements. Our engineering and commercial teams will respond with a tailored proposal.

Inquiry Now