VST Lighting Logo
waterproof t8 led tube lights
t8 led tube VST-T8-1500-22W
integrated t8 led tube
t8 led tube with G5 pin
t8 led tube light with G5 pin
t8 led tube with rotate end cap
waterproof t8 led tube lights
t8 led tube VST-T8-1500-22W
integrated t8 led tube
t8 led tube with G5 pin
t8 led tube light with G5 pin
t8 led tube with rotate end cap

1500mm T8 LED Tube for Warehouse Replacement

The VST-T8-1500-22W is a 1500mm, 22W T8 LED tube designed for warehouse lighting, workshop aisles, garages, supermarkets, and larger commercial replacement programs. Its longer body helps cover wider areas while 150lm/W efficiency supports lower operating cost. AC85V-265V input, >0.92 power factor, 50,000hrs lifespan target, and a 160° beam angle help project buyers plan reliable LED linear lighting installations. The aluminum + PC body supports heat control, and VST’s integrating sphere testing, thermal checks, aging tests, and engineering communication help reduce quality variation across bulk orders.

Key Advantages

  • 1500mm length covers wider warehouse and workshop areas while reducing the number of lamp sections.
  • 22W power and 150lm/W efficiency support lower energy cost in long daily operating hours.
  • 50,000hrs lifespan target helps reduce maintenance planning for high or difficult mounting positions.
  • Aluminum + PC housing supports heat control during extended commercial and industrial operation.
  • VST thermal verification and aging racks help protect bulk quality after sample approval.
  • Engineering communication supports CCT, PC cover, base, wiring, and IP option discussions.
  • Stable supply chain experience helps distributors manage repeat warehouse replacement purchasing.

Mounting Method

Surface Suspended

Dimming Control

Non-dimmable TRIAC 0-10V DALI Sensor

Technical Specifications

Parameter Value
Power 22W
Luminous Efficiency 150lm/w
Lifespan 50,000hrs
Input Voltage AC85V-265V 50/60Hz
Power Factor >0.92
Color Temperature 2700K-7000K
CRI > 80
Beam Angle 160°
LED Driver Constant Current Internal
Dimension D28*1514mm
Material Aluminum + PC
PC Type Clear, Frost
Lamp Base G13 or G5
IP Rate IP20 IP65 optional
Working Temperature -20°C~+50°C)
Work Humidity 10%-90% RH

Product Overview

The VST-T8-1500-22W T8 LED Tube Light is intended for larger commercial and industrial spaces where longer light runs reduce fixture count and simplify replacement planning. At 1500mm and 22W, it is suitable for warehouse lighting, workshop aisles, supermarkets, garages, production areas, logistics centers, and other projects that need reliable LED linear lighting across wider zones.

The tube delivers 150lm/W luminous efficiency, helping buyers reduce energy cost without moving to a complicated fixture system. It uses AC85V-265V 50/60Hz input, >0.92 power factor, a constant current internal driver, 160° beam angle, and aluminum + PC construction. The 50,000hrs lifespan target supports lower maintenance planning, while clear or frosted PC options help match task lighting, storage lighting, or general commercial lighting needs.

Industrial and warehouse replacement projects often expose weak suppliers. Long operating hours, high mounting positions, and repeated bulk orders make quality variation expensive. VST Lighting controls these risks through experienced engineering review, integrating sphere testing, thermal verification, aging racks, and standard quality checks from incoming material to outgoing inspection. Our engineers have around 9 years of hands-on LED lighting engineering experience, so they can respond to practical questions about brightness, heat, driver behavior, and installation compatibility.

The 2400mm T8 LED tube is the next length to review when the installation needs broader linear coverage. Check the mounting space before selection.

For distributors, electrical contractors, and project buyers, the 1500mm T8 LED tube provides a strong balance of efficiency, length coverage, and supplier support. VST can discuss CCT, CRI, PC cover, wiring, G13 or G5 base, IP20/IP65 options, OEM labeling, export packaging, and market-related certification status per SKU. It is a practical option for stable warehouse replacement programs.

Application Fit

Best For

Warehouse aisles|Workshop lighting|Garage lighting|Industrial retrofit

Compatible Applications

1500mm T8 LED tube for warehouse aisles|workshop lighting|garage lighting|industrial retrofit|large commercial replacement

Customization Options

Tailor this product to your project or integration requirements.

Support CCT, CRI, PC cover, structure, wiring, base, labeling, packaging and parameter discussions with engineering review, sample feedback, integrating sphere testing, thermal verification and practical communication for OEM/ODM or project needs.

Supply & Commercial Assurance

Minimum Order Qty

120

Lead Time

7 days for samples; 15~25 days for bulk orders depending on quantity, customization, material availability, and order schedule.

Sampling Support

Support sample orders; sample cost can be refunded after confirmed bulk order.

Supply Stability

Stable supply is supported, and stock can be discussed for key partners based on forecast and cooperation plan.

Compliance & Certifications

Certifications

CE RoHS UL

Related Content

Resources

common LED installation mistakes

Common LED Installation Mistakes in Commercial Projects

Common LED installation mistakes usually come from weak planning, not from the light source itself. In commercial projects, the main risks are wrong voltage selection, poor polarity control, undersized drivers, excessive cable length, weak mounting, and missed heat or waterproofing requirements. Fixing these early protects safety, reduces rework, and keeps the installation on schedule. A practical rule is simple: confirm the driver, wiring, mounting, and environmental conditions before the first fixture is fixed in place. If you install LED strip, linear light, or other low-voltage LED systems without checking load, current, dimming method, and IP rating, you will often see flicker, dim ends, heat buildup, or premature failure. Quick Installation Answer Power: Match the driver output voltage to the LED load, and keep a 20% load margin for stable operation and cooler running. Wiring: Verify polarity before energizing low-voltage LED strip, especially on long runs with multiple connection points. Voltage drop: Limit cable length or increase cable gauge when the run is long, because low voltage at the load causes dim ends and color shift. Mounting: Use a clean, flat, dry surface or an aluminum profile when heat dissipation and alignment matter. Dimming: Confirm the dimmer type before installation, since PWM, 0-10V, and TRIAC systems are not interchangeable. Waterproofing: Use the correct IP-rated connector, seal, and enclosure for wet or outdoor zones. Testing: Energize the system before final close-up so you can catch flicker, heat issues, or loose terminations early. Key Installation Checks Confirm the LED voltage, total wattage, and current before selecting the LED driver or power supply. Check the total cable length from driver to load, not just the visible fixture length. Verify the mounting surface, fixing method, and access for future maintenance. Confirm whether the installation area needs an aluminum profile, thermal pad, or airflow for heat dissipation. Check polarity, connector type, and splice method before energizing the circuit. Confirm the dimming method and control signal type if a dimmer or controller is specified. Confirm the IP rating and waterproofing method for damp, outdoor, or washdown locations. Review local electrical code and site safety rules before hardwiring or connecting to mains voltage.

May 23, 2026

LED lighting mismatch

How to Avoid LED Lighting Mismatch in Projects?

LED lighting mismatch happens when luminaires, drivers, controls, or installation conditions do not align, so the project does not perform as specified. The short answer is simple: avoid mismatch by matching voltage, wattage, current, CCT, CRI, dimming method, and installation environment before you order or install. That matters because even a small spec gap can create color shift, flicker, overload, uneven brightness, or failed commissioning. “If the electrical and optical parameters are not matched at design stage, the field result will rarely match the sample.” In practical terms, LED lighting mismatch affects specification accuracy, installation efficiency, maintenance risk, compliance, and total cost. It is not only a product issue. It is a system issue that includes the driver, the load, the control method, and the real site conditions.

May 23, 2026

Ready to Source or Customize?

Tell us your project specs or integration requirements. Our engineering and commercial teams will respond with a tailored proposal.

Inquiry Now