VST Lighting Logo
t8 led tube light with G5 pin
1500mm 30W T5 LED tube light for industrial and warehouse replacement projects
t5 led tube light
integrated t5 led tube
t8 led tube with G5 pin
t8 led tube light with G5 pin
1500mm 30W T5 LED tube light for industrial and warehouse replacement projects
t5 led tube light
integrated t5 led tube
t8 led tube with G5 pin

900mm T5 LED Tube for Retail and Office Linear Runs

The VST-T5-900-15W T5 LED tube is a mid-length 900mm 15W option for retail display lighting, office aisles, equipment integration, and commercial retrofit areas. With 150lm/W efficiency, 50,000hrs lifespan, >0.92 power factor, AC85V-265V input, and a 160° beam angle, it gives buyers a useful balance of length, output, and installation flexibility. The aluminum + PC body and G5 base support practical replacement planning. VST Lighting verifies performance with integrating sphere testing and can discuss CCT, cover, and structure requirements. This model fits buyers who want a non-standard length for shelves or aisles while keeping sourcing and specification control straightforward.

Key Advantages

  • 900mm format suits retail shelves and office aisles where 600mm tubes under-cover the space.
  • 15W output with 150lm/W efficiency supports brighter display lighting with controlled energy use.
  • 160° beam angle helps create wider linear coverage across showcases, counters, and work zones.
  • VST engineering support helps buyers review fit, CCT, cover style, and application details.
  • Integrating sphere and aging tests support more consistent data between samples and bulk orders.
  • Clear or frost PC choices help balance product visibility, glare control, and lighting comfort.
  • Flexible MOQ and practical communication support distributors developing mid-length T5 tube demand.

Mounting Method

Surface Suspended

Dimming Control

Non-dimmable

Technical Specifications

Parameter Value
Power 15W
Luminous Efficiency 150lm/w
Lifespan 50,000hrs
Input Voltage AC85V-265V 50/60Hz
Power Factor >0.92
Color Temperature 2700K-7000K
CRI > 80
Beam Angle 160°
LED Driver Constant Current Internal
Dimension D20*862mm
Material Aluminum + PC
PC Type Clear, Frost
Lamp Base G5
IP Rate IP20 IP65 optional
Working Temperature -20°C~+50°C)
Work Humidity 10%-90% RH

Product Overview

The VST-T5-900-15W T5 LED tube light is built for buyers who need a mid-length linear source for retail shelves, office aisles, equipment integration, and commercial display areas. At 900mm and 15W, it gives more illuminated length than a compact tube while staying easier to fit than a 1200mm model. This makes it useful for retrofit projects where existing structures, mounting space, or product design limits the available fixture length.

For procurement managers, the main value is not only brightness. This T5 LED tube combines 150lm/W efficiency, 50,000hrs lifespan, AC85V-265V 50/60Hz input, >0.92 power factor, 160° beam angle, aluminum + PC housing, and G5 base compatibility. These details support energy-saving LED tube replacement plans, reduce maintenance exposure, and make specification review clearer for electrical contractors and OEM buyers. Clear and frost PC cover choices also help balance display brightness with visual comfort.

VST Lighting supports the model with practical engineering work. Our key engineers have around 9 years of LED lighting engineering experience, and our team uses integrating sphere testing to verify lumen efficiency, CCT, and CRI. Thermal imaging and aging racks help us review heat behavior and operating stability before product data is presented to customers. This is important for buyers who have seen sample performance change during bulk orders and want a supplier that tests before it promises.

Where the available mounting length is shorter, review the 600mm T5 LED tube. Confirm the base, wiring and fixture clearance.

The 900mm format is especially relevant for retail lighting and office lighting where tube length must match shelves, showcases, service zones, or ceiling runs. VST can support discussions about CCT selection, PC cover style, structure adjustment, labeling, and integration details. For distributors and project buyers, the result is a more controlled sourcing process, clearer communication, and a T5 LED tube supplier able to support both standard commercial lighting and customized LED linear lighting applications.

Application Fit

Best For

retail displays|office aisles|showcases|equipment integration

Compatible Applications

900mm retail tube lighting|office aisle LED tube|showcase linear lighting|mid-length T5 replacement|equipment lighting integration

Customization Options

Tailor this product to your project or integration requirements.

Supports CCT selection, clear/frost PC cover, CRI discussion, structure adjustment, wiring details, labeling, and testing validation based on project needs.

Supply & Commercial Assurance

Minimum Order Qty

120

Lead Time

Samples about 7 days; bulk orders about 15-25 days depending on quantity, customization, material availability, and order schedule.

Sampling Support

Sample support available; sample cost can be refunded after order confirmation.

Supply Stability

Stable supply support available; stock planning can be discussed for key partners.

Compliance & Certifications

Certifications

CE RoHS ERP FCC

Related Content

Resources

common LED installation mistakes

Common LED Installation Mistakes in Commercial Projects

Common LED installation mistakes usually come from weak planning, not from the light source itself. In commercial projects, the main risks are wrong voltage selection, poor polarity control, undersized drivers, excessive cable length, weak mounting, and missed heat or waterproofing requirements. Fixing these early protects safety, reduces rework, and keeps the installation on schedule. A practical rule is simple: confirm the driver, wiring, mounting, and environmental conditions before the first fixture is fixed in place. If you install LED strip, linear light, or other low-voltage LED systems without checking load, current, dimming method, and IP rating, you will often see flicker, dim ends, heat buildup, or premature failure. Quick Installation Answer Power: Match the driver output voltage to the LED load, and keep a 20% load margin for stable operation and cooler running. Wiring: Verify polarity before energizing low-voltage LED strip, especially on long runs with multiple connection points. Voltage drop: Limit cable length or increase cable gauge when the run is long, because low voltage at the load causes dim ends and color shift. Mounting: Use a clean, flat, dry surface or an aluminum profile when heat dissipation and alignment matter. Dimming: Confirm the dimmer type before installation, since PWM, 0-10V, and TRIAC systems are not interchangeable. Waterproofing: Use the correct IP-rated connector, seal, and enclosure for wet or outdoor zones. Testing: Energize the system before final close-up so you can catch flicker, heat issues, or loose terminations early. Key Installation Checks Confirm the LED voltage, total wattage, and current before selecting the LED driver or power supply. Check the total cable length from driver to load, not just the visible fixture length. Verify the mounting surface, fixing method, and access for future maintenance. Confirm whether the installation area needs an aluminum profile, thermal pad, or airflow for heat dissipation. Check polarity, connector type, and splice method before energizing the circuit. Confirm the dimming method and control signal type if a dimmer or controller is specified. Confirm the IP rating and waterproofing method for damp, outdoor, or washdown locations. Review local electrical code and site safety rules before hardwiring or connecting to mains voltage.

May 23, 2026

LED lighting mismatch

How to Avoid LED Lighting Mismatch in Projects?

LED lighting mismatch happens when luminaires, drivers, controls, or installation conditions do not align, so the project does not perform as specified. The short answer is simple: avoid mismatch by matching voltage, wattage, current, CCT, CRI, dimming method, and installation environment before you order or install. That matters because even a small spec gap can create color shift, flicker, overload, uneven brightness, or failed commissioning. “If the electrical and optical parameters are not matched at design stage, the field result will rarely match the sample.” In practical terms, LED lighting mismatch affects specification accuracy, installation efficiency, maintenance risk, compliance, and total cost. It is not only a product issue. It is a system issue that includes the driver, the load, the control method, and the real site conditions.

May 23, 2026

Ready to Source or Customize?

Tell us your project specs or integration requirements. Our engineering and commercial teams will respond with a tailored proposal.

Inquiry Now