VST Lighting Logo
integrated t5 led tube
t5 led tube light
t8 led tube with G5 pin
1500mm 30W T5 LED tube light for industrial and warehouse replacement projects
t8 led tube light with G5 pin
integrated t5 led tube
t5 led tube light
t8 led tube with G5 pin
1500mm 30W T5 LED tube light for industrial and warehouse replacement projects
t8 led tube light with G5 pin

22W T5 LED Tube Light for Commercial Retrofit

The VST-T5-1200-22W is a higher-output 1200mm T5 LED tube light for commercial spaces where buyers need more brightness without changing lamp length. Its 22W power, 150lm/W efficiency, 50,000hrs lifespan, AC85V-265V input, >0.92 power factor, and 160° beam angle suit offices, classrooms, retail aisles, and retrofit projects. Aluminum + PC construction supports heat control and daily use. VST can review CCT, cover style, driver needs, and structure details for contractors, distributors, and OEM LED tube buyers. This makes it suitable when illuminance targets are higher but the existing fixture plan favors a standard 1200mm tube.

Key Advantages

  • 22W output gives higher brightness from the same 1200mm T5 tube format.
  • 150lm/W efficiency helps upgrade commercial retrofit areas without excessive energy demand increases.
  • 160° beam angle supports broad linear coverage for classrooms, offices, and retail aisles.
  • Constant current internal driver supports stable operation and clearer specification review processes.
  • VST thermal verification helps check heat behavior before production decisions are finalized.
  • G5 base compatibility simplifies replacement planning for electrical contractors and distributors teams.
  • Engineering communication supports parameter discussion, sample review, and OEM structure adjustment work.

Mounting Method

Surface Suspended

Dimming Control

Non-dimmable

Technical Specifications

Parameter Value
Power 22W
Luminous Efficiency 150lm/w
Lifespan 50,000hrs
Input Voltage AC85V-265V 50/60Hz
Power Factor >0.92
Color Temperature 2700K-7000K
CRI > 80
Beam Angle 160°
LED Driver Constant Current Internal
Dimension D20*1162mm
Material Aluminum + PC
PC Type Clear, Frost
Lamp Base G5
IP Rate IP20 IP65 optional
Working Temperature -20°C~+50°C)
Work Humidity 10%-90% RH

Product Overview

The VST-T5-1200-22W T5 LED tube light serves projects that need a stronger 1200mm output level without changing to a longer lamp. It is suited to offices with higher illuminance targets, classrooms, retail aisles, workshops, back-of-house commercial spaces, and retrofit jobs where the fixture length is fixed but the buyer wants more usable light from each tube.

At 22W, this T5 LED tube delivers 150lm/W efficiency, 50,000hrs lifespan, AC85V-265V 50/60Hz operation, >0.92 power factor, and a 160° beam angle for broad linear coverage. The aluminum + PC body supports heat control, and the G5 base keeps the model aligned with T5 replacement requirements. Clear or frost PC options let buyers choose stronger transmission or softer diffusion depending on the installation environment.

For procurement managers and electrical contractors, the commercial risk is often hidden in repeatability. A tube may look acceptable in a sample but fail to keep the same electrical, optical, or thermal behavior in bulk. VST Lighting reduces this risk through practical engineering controls. Our key engineers have around 9 years of LED lighting engineering experience, and we use integrating sphere testing to confirm lumen efficiency, CCT, and CRI. Thermal imaging cameras and aging racks also support verification before production decisions are finalized.

When the fixture allows a 1500mm lamp and needs more output, review the 1500mm 30W T5 LED tube. Confirm the G5 base and wiring before selection.

This model is a useful choice when project buyers need an energy-saving LED tube for commercial lighting where performance margin matters. VST can discuss CCT, CRI, cover type, driver requirements, structure details, labeling, and OEM integration needs. Certification availability should be confirmed by SKU and destination market. For buyers who need clear specifications, responsive technical communication, and a T5 LED tube supplier that understands project pressure, the 1200mm 22W model provides a practical sourcing option. This makes it easier to compare lighting plans, sample feedback, and final procurement decisions across several job sites.

Application Fit

Best For

higher-output office lighting|classrooms|retail aisles|commercial retrofit

Compatible Applications

high-output 1200mm T5 tube|commercial retrofit lighting|classroom LED tube|retail aisle lighting|office project replacement

Customization Options

Tailor this product to your project or integration requirements.

Supports CCT selection, clear/frost PC cover, CRI discussion, structure adjustment, wiring details, labeling, and testing validation based on project needs.

Supply & Commercial Assurance

Minimum Order Qty

120

Lead Time

Samples about 7 days; bulk orders about 15-25 days depending on quantity, customization, material availability, and order schedule.

Sampling Support

Sample support available; sample cost can be refunded after order confirmation.

Supply Stability

Stable supply support available; stock planning can be discussed for key partners.

Compliance & Certifications

Certifications

CE RoHS ERP FCC

Related Content

Resources

common LED installation mistakes

Common LED Installation Mistakes in Commercial Projects

Common LED installation mistakes usually come from weak planning, not from the light source itself. In commercial projects, the main risks are wrong voltage selection, poor polarity control, undersized drivers, excessive cable length, weak mounting, and missed heat or waterproofing requirements. Fixing these early protects safety, reduces rework, and keeps the installation on schedule. A practical rule is simple: confirm the driver, wiring, mounting, and environmental conditions before the first fixture is fixed in place. If you install LED strip, linear light, or other low-voltage LED systems without checking load, current, dimming method, and IP rating, you will often see flicker, dim ends, heat buildup, or premature failure. Quick Installation Answer Power: Match the driver output voltage to the LED load, and keep a 20% load margin for stable operation and cooler running. Wiring: Verify polarity before energizing low-voltage LED strip, especially on long runs with multiple connection points. Voltage drop: Limit cable length or increase cable gauge when the run is long, because low voltage at the load causes dim ends and color shift. Mounting: Use a clean, flat, dry surface or an aluminum profile when heat dissipation and alignment matter. Dimming: Confirm the dimmer type before installation, since PWM, 0-10V, and TRIAC systems are not interchangeable. Waterproofing: Use the correct IP-rated connector, seal, and enclosure for wet or outdoor zones. Testing: Energize the system before final close-up so you can catch flicker, heat issues, or loose terminations early. Key Installation Checks Confirm the LED voltage, total wattage, and current before selecting the LED driver or power supply. Check the total cable length from driver to load, not just the visible fixture length. Verify the mounting surface, fixing method, and access for future maintenance. Confirm whether the installation area needs an aluminum profile, thermal pad, or airflow for heat dissipation. Check polarity, connector type, and splice method before energizing the circuit. Confirm the dimming method and control signal type if a dimmer or controller is specified. Confirm the IP rating and waterproofing method for damp, outdoor, or washdown locations. Review local electrical code and site safety rules before hardwiring or connecting to mains voltage.

May 23, 2026

LED lighting mismatch

How to Avoid LED Lighting Mismatch in Projects?

LED lighting mismatch happens when luminaires, drivers, controls, or installation conditions do not align, so the project does not perform as specified. The short answer is simple: avoid mismatch by matching voltage, wattage, current, CCT, CRI, dimming method, and installation environment before you order or install. That matters because even a small spec gap can create color shift, flicker, overload, uneven brightness, or failed commissioning. “If the electrical and optical parameters are not matched at design stage, the field result will rarely match the sample.” In practical terms, LED lighting mismatch affects specification accuracy, installation efficiency, maintenance risk, compliance, and total cost. It is not only a product issue. It is a system issue that includes the driver, the load, the control method, and the real site conditions.

May 23, 2026

Ready to Source or Customize?

Tell us your project specs or integration requirements. Our engineering and commercial teams will respond with a tailored proposal.

Inquiry Now